The SBrick Protocol 4.2b12 ========================= The advertisement data ---------------------- The advertisement data contains the full device name, and some manufacturer specific data. The latter contains security and battery voltage information, and is available in the "scan response" packets in response to active scanning. Vengit Limited manufacture specific data fields ----------------------------------------------- We use manufacturer specific data in AD to advertise product type, battery reading and other data currently not in the Bluetooth specification. The manufacturer specific data starts with a length octet, that describes the whole length of this field. After the length octet, the company identifier for Vengit limited follows in little endian order. After these four bytes, the actual data payload follows. < LENGTH ><01><98>< DATA PAYLOAD > The manufacturer specific data records can be read as:<1:data length (1-255)>< Data > Every record begins with a length octet, and a record identifier octet that determines the type of the record. The manufacturer specific data field may be present in both advertisement data, and scan response data packets, even at the same time. Vengit Limited manufacturer specific data records: 00 Product type 00<1:ProductID> <2: HW major/minor version> <2: FW major/minor version>00 - SBrick Example 1: 02 00 00 - Product SBrick Example 2: 06 00 00 04 00 04 01 - Product SBrick, HW 4.0, FW 4.1 01 BlueGiga ADC sensor raw reading 01<1:channel> <2: raw sensor reading>Example, battery reading '12f0' on SBrick: 04 01 00 12 F0 Example, temperature reading '12f0': 04 01 0e 12 F0 02 Device Identifier 02 < Device identifier string > Example, SBrick device ID: 07 02 0D 23 FC 19 87 63 03 Simple Security status 05 < status code > 00: Freely accessible 01: Authentication needed for some functions Example manufacturer specific data for SBrick, containing device ID with hw/sw revision, with battery readings and device ID: 1A FF 01 98 06 00 00 04 00 04 02 04 01 0E 12 f0 07 02 0D 23 FC 19 87 63 02 03 00 The GATT database ----------------- The following service and characteristics are accessible: 1. Generic GAP service 2. Device information service 5. OTA service 6. Remote control service Generic GAP service - 1800 -------------------------- Only contains the device name and appeareance characteristics. The device name (2a00) is always "SBrick", and the appeareance (2a01) is always 0384 a.k.a. "generic remote control", according to the Bluetooth Specification. Device information - 180a ------------------------- Contains mandatory device information fields. Model number string - 00: "SBrick". Same as the "Product type" above. Firmware revision string Hardware revision string Software revision string These are version information strings. The "firmware" and "software" revision string are always the same. The revision string consist of a major and a minor revision, separated by a dot. (Example: 4.1 - Major is 4, minor is 1.) A firmware is ONLY compatible with a hardware, if their MAJOR REVISION NUMBER IS EXACTLY THE SAME. Manufacturer string - "Vengit Ltd." OTA service - 1d14d6ee-fd63-4fa1-bfa4-8f47b42119f0 -------------------------------------------------- The OTA service is compatible with BlueGiga's OTA solution, one can use BLEGui to upload a new firmware. OTA control - f7bf3564-fb6d-4e53-88a4-5e37e0326063 -------------------------------------------------- This characteristic can be used to send OTA-specific commands: 02 Reset DFU pointer Resets the DFU flash pointer to zero. Can be used when reading back firmware image. This is only useful for debugging / testing purposes. 03 Reboot into DFU mode After successfully transmitting the firmware image, the device can be booted into DFU mode with this command. In this mode, the device checks the flash memory for a firmware image, and calculates the checksum. If the checksum is correct, the firmware image is transferred into the program memory. This procedure takes approximately five seconds. After this, the firmware clears up the user flash. During flash clearing, the ID LED blinks quickly for about one and a half seconds. The characteristic can also be read. The value read back is the DFU pointer, or the number of bytes written into flash. The application might want to check the DFU pointer, and compare it with the firmware size. If the thow sizes are different, the deivce MUST be restarted with the "0x12 Reboot" command, and the user must be informed about the failure. The user flash is cleared upon reboot, and the firmware upload can be attempted again. OTA data - 984227f3-34fc-4045-a5d0-2c581f81a153 ----------------------------------------------- This characteristic can be used to transfer the firmware image in 20 byte packages. After successfully uploading the firmware, the application MUST issue a command "0x03 Reboot into DFU mode" on the control characteristic to restart the device into DFU mode. This characteristic can also be read to check the written firmare, or blank-check the flash. One must reset the DFU pointer with comman 0x02 on the control characteristic before attempting a readback. This feature is probably not that useful fin normal circumstances, as it was developed to aid development / debugging. Remote control service - 4dc591b0-857c-41de-b5f1-15abda665b0c ------------------------------------------------------------- This service contains two characteristics: * Quick Drive: allows remote control with small data packets. Very limited functionality. * Remote control commands: allows full control, more verbose and slower than quick drive. The Quick Drive characteristic should be used in situations where multiple channels must be updated quickly. It uses less bandwidth than issueing commands at the Remote control commands characteristic. The Remove control commands characteristic allows full control over SBrick. Remote control commands - 2b8cbcc-0e25-4bda-8790-a15f53e6010f ------------------------------------------------------------- Commands can be issued by writing data to this characteristic. A command always starts with the command identifier byte, after wich parameters may follow. A single BLE write operation can only send a single command. Certain commands can return a value. The returned value can be read from the characteristic. The central can also subscribe to notifications on this characteristic, so renturn values will be sent promptly when available. Commands with no return values will issue no notification, and the characteristic value will not change. The "OWNER" note means that the operation require owner privileges. All commands might throw exceptions. These exceptions manifest themselves as BLE level errors, with error codes in the user-defined error range. The possible exceptions are the following: 0x80 ERROR_LENGTH Invalid command length 0x81 ERROR_PARAM Invalid parameter 0x82 ERROR_COMMAND No such command 0x83 ERROR_NOAUTH No authentication needed 0x84 ERROR_AUTH Authentication error 0x85 ERROR_DOAUTH Authentication needed 0x86 ERROR_AUTHOR Authorization error 0x87 ERROR_THERMAL Thermal protection is active 0x88 ERROR_STATE The system is in a state where the command does not make sense The possible commands are following. 00 Break 00 < channel1 > < channel2 > ... At least one, at most four channels can be given (The default is all channels are freewheeling) Return: - 01 Drive 01 < channel1 > < direction1 > < power1 > ... (The default is all channels are freewheeling) Return: - 02 Need authentication? 02 If owner password is set, this will return true. This exact information is reflected in the "simple security" field in manufacturer specific data. Return: 00 - Authentication not needed 01 - Authentication needed 03 Is authenticated? 03 Returns wether the current session is authenticated. This will always return true, if there's no owner password set. Return: 00 - Not authenticated 01 - Authenticated 04 Get user ID 04 Returns the authenticated user ID. If the user is not authenticated, then a BLE error is returned. Return: User ID if authenticated. 05 Authenticate 05<1byte user ID> <8 byte password>New sessions are unauthenticated if password set. New sessions are authenticated if password is not set. Return: - 06 Clear password (OWNER) 06 00: clears owner password. This will "open" SBrick, anyone connecting will get owner rights. Guest password will also be cleared. 06 01: clear only guest password, rendering guests unable to authenticate. Return: - 07 Set password (OWNER) 07 < User ID ><8 byte password>: set the password 00: owner 01: guest Guest password can only be set if there is a password set for the owner too (e.g. "need authentication?" returns 1) Return: - 08 Set authentication timeout (OWNER) 08<0.1 seconds x N, minimum 1, maximum 25.5 seconds, 1 byte>Sets the authentication timeout. This value is saved to the persistent store, and loaded at boot time. Return: - 09 Get authentication timeout (OWNER) 09 Return:<1 byte auth timeout in 0.1 sec. ticks>0A Get brick ID 0A Return: < BRICK ID, 6 byte BlueGiga ID > 0B Quick Drive Setup 0B < channel-number1 > < channel-number2 > At least one, at most five channels can be given. Default: First five channels adcending order Return: - 0C Read Quick Drive Setup 0C Return:<5 byte quick drive setup>0D Set watchdog timeout 0D < timeout in 0.1 secs, 1 byte > The purpose of the watchdog is to stop driving in case of an application failure. Watchdog starts when the first DRIVE command is issued during a connection. Watchdog is stopped when all channels are either set to zero drive, or are braking. The value is saved to the persistent store. The recommended watchdog frequency is 0.2-0.5 seconds, but a smaller and many larger settings are also available. Writing a zero disables the watchdog. By default watchdog is set to 5, which means a 0.5 second timeout. Return: - 0E Get watchdog timeout 0E Return: < 1 byte watchdog timeout > 0F Query ADC 0F < ADC channel ID, 00 or 0e > The ADC channels are read at every 2 seconds. These values are stored in variables, and this query simply reads those variables. Because of this, ADC data can be up to 2 seconds old. Temperature can be read on channel 0x0E, voltage on 0x00. Return: 2 byte, little endian, 12 bit resolution ADC reading on given channel. Value is stored MSB. (Must be divided by 16) All ADC channels are using the internal 1.24V reference. The PSU voltage is dropped through a 10:1 voltage divider. VPSU = ADC / 16 * 1.24 / 2047 Temperature can be calculated as: celsius = (ADC / 16 * 1240 / 2047) * 10/45 - 160 Where 160 is an offset 10 Send event 10 < event ID > Events can be used to trigger patterns. Event range: 0-31. Events 0-15 are reserved for system use. Special events: 0: Boot. Program starts 5 seconds after boot. 1: Connection established 2: Disconnected 16-31: User events 11 Erase user flash on next reboot (compromises OTA!) 11 Return: - 12 Reboot 12 After issueing this command, the remote device will gracefully terminate the connection, and reboot in normal (non-DFU) mode. To reboot in DFU mode and possibly update firmware, use the OTA service. Return: - 13 Break with PWM support 13 < channel1 > < power1 > < channel2 > < power2 > ... (The default is all channels are freewheeling) Return: - 14 Set thermal limit 14<2 byte ADC value>Sets the thermal protection limit. Return: - 15 Read thermal limit 15 Return: 2byte, the raw ADC value set for thermal limit 16 Write program 16<2byte offset>< data > BIN MASK HEX COMMAND ============================= 00000rrr $F8 $00 DBRAKE reg(0-7, pwm, reg+1: ch) 000010cc $FC $08 BRAKE ch 000011cc $FC $0C BRAKEPWM ch pwm 00010rrr $F8 $10 DDRIVE reg(0-7, pwm, reg+1: d:1, ch:3) 00011dcc $F8 $18 DRIVE ch d pwm 00100rrr $F8 $20 DWAIT reg(0-7, reg+1) 00101ttt $F8 $28 WAIT t(0-2047, 3+8 bits) 00110rrr $F8 $30 DSETPWM reg(0-7, pwmh, reg+1: pwml) 00111000 $FF $38 SETPWM pwm(0-65535, big endian) 00111001 $FF $39 PUSHC value(0-255) 0011101a $FE $3A CALL addr(0-511) 00111100 $FF $3C RET 00111101 $FF $3D NOP 0011111a $FE $3E JMP addr(0-511) 01000rrr $F8 $40 PUSH reg(0-7) 01001rrr $F8 $48 POP reg(0-7) 01010rrr $F8 $50 MOVSL reg(0-7) reg(0-15) -> Move direction -> 01011rrr $F8 $58 MOVLS reg(0-15) reg(0-7) -> Move direction -> 01100bba $F8 $60 JUMPIF b(0-3 bit of the STATUS register) addr(0-511) 01101bba $F8 $68 JUMPIFN b(0-3 bit of the STATUS register) addr(0-511) 01110rrr $F8 $70 INC reg(0-7) 01111rrr $F8 $78 DEC reg(0-7) 10000rrr $F8 $80 ADD reg(0-7) 10001rrr $F8 $88 SUB reg(0-7) - The accumulator is decremented 10010rrr $F8 $90 MUL reg(0-7) 10011rrr $F8 $98 DIV reg(0-7) - The accumulator is divided. Can overflow, mod can still be used 10100rrr $F8 $A0 AND reg(0-7) 10101rrr $F8 $A8 OR reg(0-7) 10110rrr $F8 $B0 XOR reg(0-7) 10111rrr $F8 $B8 SHL reg(0-7) 11000rrr $F8 $C0 SHR reg(0-7) 11001rrr $F8 $C8 LOAD reg(0-7) value(0-255) 11010000 $FF $D0 DEBUG - Send regs:pc and stack:sp in a notification on the command characteristic 11010001 $FF $D1 RESET - Clears all registers and the stack. PC advances as usual. 11111111 $FF $FF STOP - There are 16 registers - Registers have 8-bit values - The lower 8 registers are addressable with 1-byte commands Special registers: ACC, 0x00: accumulator, arithmetic commands put their values there ACCH, 0x01: in case of mul and div, the MSB and the remainder are put here STATUS, 0x0F: has CARRY (or borrow), OVERFLOW, ZERO, SIGN bits (0-3) Example: 16 0000 1860 2809 1C60 2809 3E00 - Write program to address 0 DRIVE 0 0 0x60 WAIT 1.0s DRIVE 0 1 0x60 WAIT 1.0s JMP 0 Dynamic braking (using regs 1 and 2): 16 0000 1860 2809 C9FF CA00 01 2809 3E00 ...on channel 1: 16 0000 1960 2809 C9FF CA01 01 2809 3E00 Load once, use in loop ddrive&brake (regs 0-2): 16 0000 C8FF C900 CA00 CB09 10 22 00 22 3E08 Use dynamic PWM 16 0000 C877 C972 CA3B CBB9 1810 30 2804 32 2804 16 1000 3E0A More complex program to demonstrate PWM frequency change capabilities by playing a nice tune ;) 160000182338EEE4280638BD9B280638EEE42806 16110038BD9B2806389F71280B18002801182338 1622009F71280A18002801182338EEE4280638BD 1633009B280638EEE4280638BD9B2806389F7128 1644000B180028011823389F71280A1800280118 165500103877722806387E8C2806388E0C280638 1666009F71280638B2F7280B180028011823388E 1677000C280A180028011823389F71280638B2F7 168800280638BD9B280638D4D3280638EEE4280B 16990018002801182338EEE4280B1800FF Imperial march 160001389F711827280618002800182728061800 1611012800182728061800280038D4D418272805 1622013886132802389F7128061800280038D4D4 163301182728053886132802389F712807180028 16440106386A6A18272806180028001827280618 1655010028001827280618002800386471182728 16660105388613280238A8EC28061800280038D4 167701D4182728053886132802389F7128071800 168801FF enjoy ;) 17 Read program 17<2byte offset> <1 byte data length>The offset + data length must be at most 512. Data length must be at most 22 bytes. Return: < data > 18 Save program 18 Saves the current program to the upper half of the first flash page, after erasing the whole page. Interferes with OTA. Return: - 19 Erase program 19 Erases the first user flash page. The command buffer will remain unaffected. Return: - 1A Set event 1A<1byte event ID> <1 byte program memory offset>Sets a program memory address for an event in the event table. Return: - 1B Read event 1B<1 byte event ID>Reads an address from the event table Return:<1 byte program memory address>1C Save events 1C Saves the event table onto the flash 1D Start program 1CD<2 byte address, 0x0000 - 0x01FF>Start program at given address 1E Stop program 1E Stops the currently running program 1F Set PWM counter value 1F<2 byte value to be written to T1CC0H/L registers>Sets the PWM counter value by writing into the TIMER1 control registers. Certain TIMER1 register values are also recalculated to keep the PWM duty cycle as constant across changes as possible. The default PWM value is 20 Get PWM counter value 20 Returns the 2 byte TIMER1 T1CC0H/L value. Return<2 byte T1CC0H/L value>21 Save PWM counter value 21 Saves PWM counter value to flash 22 Get channel status 22 Returns the current drive level of a channel Return < brake status bits, 1 byte, 1:brake on, 0: brake off ><1byte direction flags> <5 byte channel drive values from 0 to 4>23 Is guest password set (OWNER) 23 Return: 1 or 0 24 Set connection parameters 24 < interval min *1.25ms, 2 bytes > < interval max *1.25ms, 2 bytes > < slave latency, 2 bytes > < timeout *10ms, 2 bytes > Return:<1 byte return value of Bluegiga BLE stack function "connection_update">25 Get connection parameters 25 Return: < connection interval * 1.25ms, 2 bytes >< slave latency, 2 bytes >< timeout * 10ms, 2 bytes > 26 Set release on reset 26<1 byte, 0, or 1>1: Default: the channel drive values are set to zero, non-braking, and default "0" direction (clockwise with LEGO motors) 0: The channels are left in whatever state the controlling application set them. This option itself is preserved throughout connections. 27 Get release on reset 27 Return:<1 byte, 0 or 1>Quick Drive - 489a6ae0-c1ab-4c9c-bdb2-11d373c1b7fb -------------------------------------------------- The purpose of this characteristic is to make remote contgrolling possible using as little bandwidth as possible. A two-channel race car can be controlled by sending only two bytes: one for the accelerator and one for steering. One can write (no response) 0-5 byte data packets to this characteristic to drive channels. The characteristic can be thought of as a five byte register. Each byte in the register conrtols one channel. With the 0x0A "Quick Drive Setup" command, one can configure which byte controls which channel. The default is that byte 0 controls channel 0, byte 1 conrtols channel 1, and so on. Quick Drive is the recommended way to control models where low latency is expected, and there might be dozens of models in the same area. Since each channel is driven with one byte, the direction and the PWM information must be fitted into that single byte. This is done in the following way: Example: "Drive forward (clockwise) 255" 1 1 1 1 1 1 1 0<- Direction bit _ _ _ _ _ _ _ _ MSb LSb Example: writing the byte string 00FFFE00 will turn channel #1 CCW full speed, channel #2 CW full speed, and set channels #0 and #3 freewheeling. - Braking happens when the value is set to zero (less the direction bit). - When the value is 2 (less the direction bit), it is modified to 0. - When the value is 0xFE (less the direction bit), it is modified to 0xFF The last two modification make full and zero throttle possible.